The STencil Cleaner cleaning series are water-based cleaning media for cleaning SMT stencils at room temperature.
SYS-CLEAN STC1.0 reliably solder paste from stencils and misprints.
SYS-CLEAN STC1.0 is delivered as ready-to-use.
SYS-CLEAN STC2.0 cleans additionally adhesive and failed printed circuit boards.
SYS-CLEAN STC2.0 is available as concentrate and ready-to-use.
SYS-CLEAN STC3.0 is through its alkalinity also suited for misprinted circuit boards, which are already fitted on one side.
SYS-CLEAN STC3.0 is delivered as ready-to-use.
The Maintenance Cleaner cleaning series are nearly odorless, water-based, alkaline cleaning media for cleaning of solder frames and equipment, oven parts and filters at room temperature.
SYS-CLEAN MC1.0 reliably cleans burnt flux residue, oils and grease.
SYS-CLEAN MC1.0 is available as concentrate and ready-to-use.
SYS-CLEAN MC2.0 reliably cleans burnt flux residue, oil and grease, and is specially optimized for the gentle cleaning of sensitive metal components made of copper and brassin an immersion bath.
SYS-CLEAN MC2.0 is delivered as concentrate.
The Board Cleaner cleaning series are water-based cleaning media for flux removal of printed circuit boards, ceramic substrates, lead frames and power modules. The media can either be sprayed or be used in immersion or ultrasonic cleaning systems.
SYS-CLEAN BC1.0 is best suited to prepare surfaces for subsequent wire bonding and coating operations. BC1.0 is specifically additivated in order to protect very delicate surfaces from unwanted chemical reactions.
SYS-CLEAN BC1.0 is delivered as concentrate.
The WIPES are soaked with a water-based cleaning medium and optimized for immediate use. Due to the unobtrusive odor they are pleasant to handle.
SYS-CLEAN WIPES1.0 are special wipes for pre-cleaning of SMT stencils and other stainless steel surfaces, as well as squeegees, spatulas and similar.
ELITE Liquid Penetrants own new features to meet your needs of all times:
Material safety data sheets
In 16 points with physical-chemical data.Test Certificate
For each batch Sulfur and Halogen free
LIQUID PENETRANTSK 71B2p RED LIQUID PENETRANT
Water washable (Type II Method A). The deep red color shows sharper indications, perfect washability on all difficult surfaces like fused and forged with shorter penetration time.
D112A WHITE DEVELOPER
Fast surface covering and drying, save testing time and money, with high reliability.
BC1 SOLVENT
Fast drying, chlorinated solvents free. Can be used both in precleaning of dirty or grease from the surfaces and for penetrant removing when the use of the water is forbidden.
SPECIAL LIQUIDK 71HT BIO.PENETRANT RED @ 200°C
Red penetrant for high temperatures testing up to 200°C (400°F).
D200 BIO.DEVELOPER WHITE @ 200°C
White developer for high temperatures testing up to 200°C (400°F).
RHT1 REMOVER @ 200°C
Remover for high temperatures testing up to 200°C (400°F).
K71B2 BIO
Water- based liquid penetrant used with Elite DWS2 water-suspendible white developer for:
– same sensitivity of traditional oil-based penetrants (Level 2)
– no indication of danger under Reach / CLP (not marked Xn = non-harmful, not marked F = non-flammable, free of petroleum)
– free from volatile organic compounds (V.O.C.) do not need air treatment with activated charcoal (check with local environmental protection companies)
– cheaper than traditional oil-based penetrants
FLUORESCENTK 81B (level 1) – K81B/T (1/2 level) – K81B2 (level 2) FLUORESCENT LIQUID PENETRANT
Easy flaws detection, sharp and bright, with perfect washability on all difficult surfaces like fused and forged, aluminum and light alloys. Self-developing: let you avoid the developer application, saving also on final cleaning time.
K 81P (level 1) – K81P2 (level 2)- K81P3 (level 3) – K81P4 (level 4) FLUORESCENT LIQUID PENETRANT
Fluorescent Liquid Penetrant K81P is a water washable type, with sensitivity level 1.
K 81PE (level 1) – K81PE2 (level 2)- K81PE3 (level 3) – K81PE4 (level 4)- FLUORESCENT LIQUID PENETRANT
Post-emulsifiable fluorescent penetrant designed for inspection of critical parts, turbines blades, assemblies, welds. Type 1, method B, C, D, level 1.
ELITE 20 DETERGENT PROTECTIVE
Neutral product, to be used hot, diluted in water. Best substitute of chlorinated or alkaline solvents in penetrants systems because it is completely compatible with liquid penetrants.
When aluminum castings checked in automated penetrant sistem have an high fluorescent background
The Solution is
To use our fluorescent penetrant ELITE K81 B water base: easily washable with water, non-toxic and self developing, non flammable, biodegradable over 90%
To be used with our neutral PH detergent ELITE 20
Results
Sharp, clear fluorescent indications without background
Advantages
– No oven drying necessary after pre-cleaning
– Polluting substances reduced by 60%
– Self developing
Increase production, minimise costs
Ask us for a customized solution
Innovative testing media offer cost reduction in several areas of the production chain – not only the product cost.
WATER-BASED FLUORESCENT LIQUID PENETRANT K81B-K81B/T-K81B2
Instructions
1- Pre-cleaning: a good cleaning is essential to obtain reliable indications and to reduce the fluorescent background. Clean the surface by rapid evaporation solvent Elite BC1 (flammable) or by protective detergent Elite 20, the only compatible with Elite K81B that can be used directly in sequence without the steps of rinsing and drying before applying product Elite K81B.
2- On the surface cleaned by Elite 20 apply a thin layer of K81B by spraying, dipping, or brush application.
3- A 2 to 20 minute dwell time is suggested. Allow the penetrant to drain from the part: it allows penetrant savings and improves performance.
4- In order to remove penetrant, wash with water at ambient temperature. Avoid washing penetrant with high water pressure or high temperatures.
Washing with water may be preceded by a pre-wash with Elite E81B emulsifier diluted in water from 0.5 to 10%. This allows the elimination of fluorescent background from “difficult” surfaces and a considerable reduction of water consumption by allowing water recycling.
5- Drying: begin drying procedure immediately after the water wash; do not allow water to stand or puddle on the part’s surface. Compressed air is recommended to disperse and remove any surface water before placing the part into the oven. Place part in a re-circulating oven set no higher than 70°C, just long enough to evaporate surface moisture. Use a heat gun to dry parts too large to fit in oven; avoid overheating.
6- Developing: K81B is self-developing, although a developer can be used. Developing time remains mandatory according to the Standards (2 ÷ 20 minutes about).
7- Inspection: inspect part under appropriate UV light intensity.
Shelf life: 5 years from manufacturing date. Keep away from direct sunlight.
NB: Water based composition implies that at temperatures close to 0°C the product may become cloudy and even freeze. This does not modify its characteristics: it is just necessary to bring the product back to the working temperature range according to the Standards (10°C – 50°C) before use.
How to order
PRODUCTS | Spray Can Code | 10 L. TIN Code |
K 71 B2p red penetrant | 08.115 | 08.119 |
D 112 A white developer | 08.113 | 08.123 |
BC 1 solvent | 08.111 | 08.121 |
K71B2 bio red penetrant | 08.122 | |
DWS2 WATER-SUSPENDIBLE POWDER DEVELOPER (available only in 20Kg) |
08.125 | |
K71HT red penetrant high temperatures | 08.174 | 08.171 |
D200 developer high temperatures | 08.173 | 08.170 |
RHT1 remover high temperatures | 08.172 | |
K 81 B fluorescent penetrant | 08.103 | |
Elite 20 detergent protective (available only in 50Kg or 200kg) |
08.141 | |
K 81 P fluorescent penetrant | 08.130 | 08.108 |